DOLPHINMED delivery Pediatric-neonate intensive care unit ventilator that makes a excellent weaning performance in Intensive Care Units- NICU,operation room, anesthesiology department and other departments.
DOLPHINMED delivery neonate intensive care unit ventilator that makes a excellent weaning performance in Intensive Care Units- NICU,operation room, anesthesiology department and other departments.
v More convenient operating and display systems for clinical operation,suitable for pediatric and infant
v With Non-invasive and invasive ventilation function
v With sensitive pressure and flow double trigger function.
v Integrated expiration module could be sterilized whole, ensure use safely and no cross-infection.
v Comprehensive Safety&Alarm system,make sure the operation accuracy and stability
v Easy to use interface design,12.1 color touch-screen TFT display and shuttle knob design, quick and efficient operation
v Integrated expiration module build-in heating system could be sterilized whole, ensure use safely and no cross-infection; no-water design, guarantee the precious detection.
v Simultaneously display of Three Waveforms&Two Loops,ETCO2 &SPO2(optional)
v Build-in inspiratory and expiratory flow sensor, durable and water coagulation resistant.
v Maintenance-free imported flow sensor with heating and filtration technology
v Automatically inspiratory synchronous nebulizing function, nebulizing time adjustable;with tidal volume compensation(1-30 min)
v Powerful ventilation mode meet all complex clinical requirement
v Three-level visual and audible alarm information system
v The core components are imported from top international and original, and the industrial control chip is chosen
v High precious sensor and valve technology make sure the pressure ,flow and volume monitor and control at high safety, stability and precision
v Built-in backup battery provide the emergency power supply to the unit.
v VGA connector could output the screen signals to other screens
v High quality trolley with concise structure and good appearance, easy to assemble and detach.
v Lung mechanics parameter
v Up to 15000 alarm event review
v 72-hours numerical&graphical trend review
v 72-hours breath to breath waveform trend review
v With Inspiration hold&Expiration hold,Manuel Breath and 100% O2 Flushing
v Lowest in class bias flow 2.0lpm,low O2 consumption
v Automatic tube&leakage compensation technology
v Upgradable to main stream Capnography(EtCO2)&Pulse Oximetry(SPO2)
Patient Type:Pediatric,infant(optional)
Tidal volume:Pediatric 20-350ml; Infant:2-100ml
Frequency: Pediatric1-150 bpm; Infant:1-200bpm
Inspiration time:pediatric 0.1-12s,infant:0.1-3s
Monitoring parameter:Ppeak,Pmean,Pplat,PEEP,Vti,Vte,MVe,MV_cont.,MV_spont, F_Ppeak_insp,F_Peak_Exp,Leak%,Freq,F_cont,F_spont,%F_Spont,I:E,Ti,Te,Ti/T total,FiO2,(SPO2,EtCO2-Optional),Cstat,Cdyn,Rins,Rexp,RSBI,WOB,Auto PEEP,MIP,PO.1
Alarm:Audio and visual alarms
Volumes:VTe high/low.Mv MV high/low,TIdal volume not reached,HIgh leak,
Pressure:Peak Pressure high/low,Pressure limitation.O2 supply high/low/fail,Air supply pressure high/low/fail,Apnea,Apnea Backup,Freq high/low,FiO2 High/low,Circle Block,Circuit disconnection
Power:AC power fail,Low battery,Battery too low
FIO2:21%-100%(0-5 minutes)
Flow Trigger:0-20L/min
Pressure Trigger:-20-0 cmH2O
Pressure Control:5-120 cmH2O
Pressure Support:5-120 cmH2O
I:E ratio:1:9.9-9.9:1
Electronic PEEP:0-50 cmH2O
Nebulizer:0-30 minutes(optional)
100% O2:0-5 minutes
Waveforms:P-T,F-T,V-T,ETCO2 &SPO2(Optional)
Loops: P-V,P-V,P-F(optional)
Recall/Reviews: 1500 alarm events,
72 hours Trend Numerical&Graphical(optional)
72 hours Breath to Breath Waveform Review(Optional)
General info:
Communication Interface:VGA,USB,RJ45
Screen:12.1 inch color TFT with Touch Screen
Net weight:12kg
Battery:120 minutes
Air/Oxygen Gas supply:2.4 to 6.0 bar,Air compressor(Optional)
Power supply:100-240VAC,50/60Hz.1A(Max)